normally open / closed programmable; 4...20 mA or 0...10 VOutput function
150 (...80°C) / 200 (...60°C) / 250 (...40°C)Current rating [mA]
< 2.5Voltage drop [V]
pulsedShort-circuit protection
yesOverload protection
≤ 170Switching frequency [Hz]
4...20 mA; 0...10 VAnalogue output
4...20 mA: max. 500Max. load [Ω]
0...10 V: min. 2000Min. load resistance [Ω]
Measuring / setting range
0...40 MPa0...5800 psi0...400 barMeasuring range
Setting range
0.4...40 MPa40...5800 psi4...400 barSet point, SP
0.2...39.8 MPa20...5780 psi2...398 barReset point, rP
0.2 MPa20 psi2 barin steps of
Accuracy / deviations
Accuracy / deviations
(in % of the span)
< ± 0.5Switch point accuracy
< ± 0.25 (BFSL) / < ± 0.5 (LS)Characteristics deviation *)
< ± 0.25Hysteresis
< ± 0.1Repeatability **)
< ± 0.05Long-term stability ***)
Temperature coefficients (TEMPCO) in the temperature range -25...80° C (in % of the span per 10 K)
0.2Greatest TEMPCO of the zero point
0.2Greatest TEMPCO of the span
Reaction times
0.3Power-on delay time [s]
< 3
Min. response time switching
output [ms]
0...50Delay time programmable dS, dr [s]
0...4
Damping for the switching output
(dAP) [s]
0...4
Damping for the analogue output
(dAA) [s]
< 3Response time analogue output [ms]
yesIntegrated watchdog
Software / programming
hysteresis / window function; NO / NC; on delay, off delay; damping; display unit;
current/ voltage output
Programming options
Interfaces
IO-Link Device
COM2Transfer type
1.1IO-Link revision
IEC 61131-9SDCI standard
427 d / 00 01 ab hIO-Link Device ID
Smart Sensor: Process Data Variable; Device Identification, Device DiagnosisProfiles
PN3570
Pressure sensorsPN-400-SEG14-MFRKG/US/ /V